ENGINEERING DATA:
|
Cell Chemistry: Zinc Air Designation: ANSI/NEDA – 7003ZD, IEC – PR44 Recommended Use: Hearing Aid Instruments Nominal Voltage: 1.4 volts Approximate Weight: 1.77 grams (.06 oz) Approximate Volume: .57 CU CM (.035 CU IN) Standard Capacity: 300 hours – 620 Ohm 12 hours/day to 0.9 volts at 70°F (21°C) and 50% RH.
High Rate Pulse: 65 hours – 8 mA background, 24 mA 100 ms pulse, once/every 2 hours, 12 hours/day to 1.05 volts at 70°F (21° C) and 50% RH. Storage Loss at 70°F (21°C): Less than 5% in one year With tab applied. Environmental: Rayovac Material Safety Data Sheets Activation And Use: Remove and discard the plastic tab covering air holes. Allow the battery to stand for one minute to insure proper activation. The battery compartment must allow for an adequate oxygen supply to reach air holes. |
|
This data is subject to change. Performance information is typical. Contents herein do not constitute a warranty. |